We are major in serial port application environment since 1990.

Find serial port connection solution, check with RAYON anytime.

It can be used as Serial Port Expander, Serial Port Splitter, Serial Port Sharer, Broadcast & Receive Device to support Polled/Response SCADA Network.

1. PCI card to support Broadcast & Receive Device.

   a) AP1T2 card: one COM port  to 2 serial port connectors for external connection.

     support one application software to broadcast same data in 2 external connection and receive response data.

    AP1T2/3 model can support RS232/RS422/RS485 settable interface in both connectors.

    AP1T2/2 model can support RS422/RS485 settable interface in both connectors.

    AP1T2/1 model can support RS232 interface in both connectors.

   b) AP2T1 card: two COM port to 1 serial port connector for external connection.

   support two application software in two COM port to process same received data from external device.

    AP2T1/3 model can support RS232/RS422/RS485 settable interface in connector.

    AP2T1/2 model can support RS422/RS485 settable interface in connector.

    AP2T1/1 model can support RS232 interface in  connector.

   c) AP1T2I card: one COM port  to 2 serial port connectors for external connection with GROUND isolated feature.

     support one application software to broadcast same data in 2 external connection and receive response data.

    AP1T2I/3 model can support  GROUND isolated RS232/RS422/RS485 settable interface in both connectors.

    AP1T2I/2 model can support  GROUND isolated RS422/RS485 settable interface in both connectors.

    AP1T2I/1 model can support  GROUND isolated RS232 interface in both connectors.

   d) AP2T1I card: two COM port to 1 serial port connector for external connection with GROUND isolated feature.

   support two application software in two COM port to process same received data from external device.

    AP2T1I/3 model can support  GROUND isolated RS232/RS422/RS485 settable interface in connector.

    AP2T1I/2 model can support  GROUND isolated RS422/RS485 settable interface in connector.

    AP2T1I/1 model can support  GROUND isolated RS232 interface in  connector.

    

2. USB box to support Broadcast & Receive Device.

  a) UTS1T2 box:  USB to one COM port with 2 serial port connectors for external connection.

     support one application software to broadcast same data in 2 external connection and receive response data.

    UTS1T2/3 model can support RS232/RS422/RS485 settable interface in both connectors.

    UTS1T2/2 model can support RS422/RS485 settable interface in both connectors.

    UTS1T2/1 model can support RS232 interface in both connectors.

  b) UTS2T1 box: USB to two COM port with 1 serial port connector for external connection.

       support two application software in two COM port to access same data received from external connection.

    UTS2T1/3 model can support RS232/RS422/RS485 settable interface in connector.

    UTS2T1/2 model can support RS422/RS485 settable interface in connector.

    UTS2T1/1 model can support RS232 interface in  connector.

  

3.IP network box to support Polled/Response SCADA Network.

   a) APORT100P box:  Ethernet to one COM port with 1 pass-through RS232 connector and 1 RS232  connector  for external connection.

     support one application software in remote site to access RS232 device via Ethernet connection and one local control console to access via local pass-through connection. It is very easy for current local control console in machine to offer networked capability.

   b) APORT111 box: Ethernet to one COM port with 1 RS232 connector and 1 Ground isolated RS485 connector  for external connection.

       support one application software to broadcast same data in 2 external connection and receive response data. 1 RS232 connector can connect with RS232 equipment and 1 GROUND isolated RS485 connector can connect with external RS485 network safety.

   c) APORT201 box: Ethernet to two COM port with 1 RS232 pass-through connector and 1 Ground isolated RS485 connector  for external connection.

           support two application software in remote site to access external RS485 device via Ethernet connection and one local control console to access via local RS232 pass-through connection. It is very easy for current local control console in machine to offer networked capability. We may have two PC in different location to create one virtual COM for each PC to run application software.

  d) APORT210 box: Ethernet to two COM port with 1 RS232 pass-through connector and 1 Ground isolated RS232 connector  for external connection.

           support two application software in remote site to access external RS232 device via Ethernet connection and one local control console to access via local RS232 pass-through connection. It is very easy for current local control console in machine to offer networked capability. We may have two PC in different location to create one virtual COM for each PC to run application software.

  e) APORT400SR box: Ethernet to four COM port with 1 RS232  connector  for external connection.

           support four application software in remote site to access external master RS232 device via Ethernet connection. It is very easy for one master device to send data for up to four connections simultaneously. We may have four PC in different location to create one virtual COM for each PC to run application software to share same data source.

  f) APORT800SR box: Ethernet to eight COM port with 1 RS232  connector  for external connection.

           support eight application software in remote site to access external master RS232 device via Ethernet connection. It is very easy for one master device to send data for up to eight connections simultaneously. We may have eight PC in different location to create one virtual COM for each PC to run application software to share same data source.

¡@

4. Serial Port Sharer box to support Polled/Response SCADA Network.

   a) S232 box: one RS232 master serial port to 3 RS232 slave serial port.

   b) S234io box: one GROUND isolated RS232 master serial port to 3 GROUND isolated RS485 slave serial port.

   c) S432io box: one GROUND isolated RS485 master serial port to 3 GROUND isolated RS232 slave serial port.

   d) S434 box: one RS485 master serial port to 3 RS485 slave serial port.

   e) S272 box: one RS232 master serial port to 7 RS232 slave serial port.

   f) S474 box: one RS485 master serial port to 7 RS485 slave serial port.

   g) S232io box: one GROUND isolated RS232 master port to 3 GROUND isolated RS232 slave port.

   h) S434io box: one GROUND isolated RS485 master port to 3 GROUND isolated RS485 slave port.

   i) S472i box: one Ground isolated RS485 master serial port to 7 RS232 slave serial port.

 5. Intelligent Serial Port Sharer box to support Broadcast & Receive Device.

   a) IS400 box: one RS232 master serial port to 3 RS232 slave serial port. MODBUS master device in master serial port and all slave devices in slave port. Data received in master serial port will broadcast to all slave serial ports.

   b) IS800 box: one RS232 master serial port to 7 RS232 slave serial port. MODBUS master device in master serial port and all slave devices in slave port. Data received in master serial port will broadcast to all slave serial ports.

   c) IS040 box: one GROUND isolated RS232 master port to 3 GROUND isolated RS232 slave port. MODBUS master device in master serial port and all slave devices in slave port. Data received in master serial port will broadcast to all slave serial ports.

   d) IS080 box: one GROUND isolated RS232 master port to 7 GROUND isolated RS232 slave port. MODBUS master device in master serial port and all slave devices in slave port. Data received in master serial port will broadcast to all slave serial ports.

   e) IS004S box: one GROUND isolated RS485 master port to 3 GROUND isolated RS485 slave port. Multiple MODBUS master device in slaver serial port and all slave devices in master port. Data received in master serial port (ACK packet) will send back to  slave serial port for master device to poll.

   f) IS008S box: one GROUND isolated RS485 master port to 7 GROUND isolated RS485 slave port. Multiple MODBUS master device in slaver serial port and all slave devices in master port. Data received in master serial port (ACK packet) will send back to  slave serial port for master device to poll.

¡@

Please check www.rayontech.com.tw for English service.

Please check www.rayontech.com.cn for Chinese service. Or www.rayontech.com.tw for local service.

Please send mail to info@rayontech.com.tw or rayon@ms1.hinet.net for service.

RAYON Technology Co., Ltd.

2F, No.177, Chung_Shan 2 Rd., Lu_Chou, New Taipei City, Taiwan,R.O.C.

TEL: 886-2-82858362

FAX: 886-2-82857065